DuraVent

DuraFlex® Pro

DuraFlex® Pro is the ultimate in flexible steel liners for strength and flexibility. It features 20% more stainless steel per foot compared to other liners on the market. Its extreme flexibility facilitates problem free installations where multiple offsets are needed. DuraFlex Pro is available in 3″ through 12″ diameters in lengths, kits and custom lengths. DuraFlex Pro is manufactured utilizing highly corrosion resistant 316 Stainless Steel. Listed to UL 1777 and ULC S635.

DuraFlex SW

DuraFlex SW is a smooth inner-wall, flexible stainless steel chimney liner. The smooth inner wall provides for no output reduction allowing for full appliance efficiency. Smooth wall construction eliminates ridges that restrict flue gas flow and collect deposits. The lack of ridges facilitates cleaning and maintenance. DuraFlex SW is ideal for relining masonry chimney for wood and gas burning appliances. Listed to UL 1777.

DuraFlex 316 & 304
DuraFlex 304 and 316 are lighter, more economical liners. Excellent when there are minimal offsets in the chimney. DuraFlex 304SS and 316SS are intended for wood burning, non-condensing gas and oil fired appliances. Where greater corrosion resistance is desired, such as coal-fired appliances, DuraFlex 316 is recommended. DuraFlex 304SS and 316SS are listed to UL 1777 and ULC S635. 

Applications
DuraFlex Pro ultra flexible relining for masonry chimney. Use with gas, wood pellet, oil, or wood appliances. Applications include: fireplace inserts, furnaces, boilers, and water heaters.
DuraFlex SW smooth wall flexible relining for masonry chimney. Use with gas, wood pellet, oil, or wood appliances. Applications include: fireplace inserts, furnaces, boilers, and water heaters.
DuraFlex 316 flexible relining for masonry chimney. Use with gas, wood pellet, oil, or wood appliance. Applications include: fireplace inserts, furnaces, boilers, and water heaters. 316 is designed for use in harsher conditions, for more resistance to corrosion, such as coal.
DuraFlex 304 flexible relining for masonry chimney. Use with gas, wood pellet, oil, or wood appliances. Applications include: fireplace inserts, furnaces, boilers, and water heaters.

Materials and Construction
DuraFlex Pro: Single-wall .005″ 316 stainless steel.
DuraFlex SW: Single-wall .005″ overlapped 316 stainless steel (totalling .010″). Overlapped to create smooth inner wall.
DuraFlex 316 & 304: Single-wall .005” 316 or 304 stainless steel.

Clearances
DuraFlex Pro: 0″ clearance for gas, oil, and pellet applications. 1″ clearance to masonry for wood-burning applications. Insulation is required for 0″ clearance to masonry for wood-burning.
DuraFlex SW: Clearances 0″ clearance for gas, oil, and pellet applications. ” clearance to masonry for wood-burning applications. Insulation is required for 0” clearance to masonry for wood-burning.
DuraFlex 316 & 304: 0″ clearance for gas, oil, and pellet applications. 1″ clearance to masonry for wood-burning applications. Insulation is required for 0″ clearance to masonry for wood-burning.

Diameters
DuraFlex Pro & SW: 3″ – 12″.
DuraFlex 316 & 304: 3″ – 8″.

Listings
DuraFlex Pro: Listed to UL 1777 and ULC S635 (MH45609).
DuraFlex SW: Listed to UL 1777 (MH45609).
DuraFlex 316 & 304: Listed to UL 1777 and ULC S635 (MH45609).

Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation.

  • The inner pipe diameter should match the outlet size of the appliance.
  • Check the appliance manufacturer’s installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). Also, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc.
  • Be fire safe! Use proper support and bracing. Follow local building codes and have your venting system inspected.

More Typical Installations:

Installation Key
1DuraFlex SS Cap
2DuraFlex AL Cap
3DuraFlex Top Plate
4DuraFlex (SW, Pro, 304, 316) Length
5DuraFlex AL Length
6DuraFlex SS Tee
7DuraFlex AL Tee
8DuraFlex Mortar Sleeve
9DuraFlex AL Coupling
10DuraFlex SS Connector
11PelletVent Pro Appliance Adapter
12DuraBlack Trim Collar
13Rigid Type B Gas Vent
14Rigid PelletVent (L Vent)
15ProFoil Insulation, AluFoil Tape & ProMesh
16DVL or DuraBlack Pipe
17Pipe Collar (B-Vent)
 

Planning Your Installation:

1Verify the venting requirements of the appliance used. Choose the liner system appropriate for the appliance and installation.
2Refer to the Typical Installations for the type of liner installation similar to your situation. Identify the needed parts for installation.
3The size of the liner should match the outlet size on the appliance or the size of the vent/manifold that penetrates into the masonry chimney.
4Determined the length of the liner needed.
5Make sure of a proper fit for the Top Plate of the reliner to provide a secure, leak-proof installation.
6If a free-standing appliance is used, select the vent or stovepipe pieces to connect from the appliance to the liner (refer to the appropriate section of catalog).
7Important! Check to be sure the installation complies with all local and national code requirements, including clearance to combustibles. Contact the local building inspector for permit requirements.

Design Recommendations

  • The following design recommendations are intended only as a general guideline to assist in the design and selection of liner components for your installation. Always read and follow DuraVent Installation instructions (enclosed with the cap or support box) before installing DuraFlex. Installation instructions can be viewed online at www.duravent.com, under catalogs and instructions.
  • Before relining a chimney, it should be cleaned and inspected to verify the integrity of the mortar and masonry. In addition, have a certified chimney professional determine if the masonry was constructed with 0” or 1” clearance to the surrounding combustibles. This is an important fire safety issue that may have an influence on how the liner is installed.
  • Be sure to select the proper liner for the application. DuraFlex SS is used for appliances that use oil, wood, or wood-pellets for fuel; DuraFlex AL is for a non-condensing gas appliance. Refer to the appliance manufacturer for installation requirements affecting venting. Keep the vent path as straight as possible for best performance.

DuraVent is the first manufacturer to have a UL-listed relining system for factory-built chimneys to be used with solid-fuel appliances in the USA. When a homeowner installs a wood-burning insert into an existing UL127-listed fireplace, relining the existing chimney is critical for performance and safety. Check out the installation video on our youtube channel.

Product Bulletin:

What does the UL listing cover?
All 127, 103, or 103HT chimneys
Insulated chimneys- all sizes with 2” clearance
Air cooled – clearance based on diameter
All Duravent UL1777 systems up to 8”
Flex does not need insulation.

Air Cooled Chimney Coverage:
Up to 8” I.D. chimneys with at least 1 ¼” wall (ex. 8×10½)
6×8½ is OK, 8×11 is OK
Up to 8” I.D. chimneys require at least 1 ½” clearance
Larger chimneys with at least 1 ½” wall (ex. 10×13)
9×12 is OK, 10×14 is OK, 16×19 is OK
Chimneys larger than 8” require at least 2” clearance

Factory-Built Reline Kit includes:
Cap
Storm Collar
Support Bracket
Ventilation Disk
Centering Bracket
DuraLiner 12” Length
Flex Connector
Flex Length (25’ or 35’)
Adjustable Band
Flex Adapter